MEGA-600
General
specification
· Input (according to tables)
· PID control
· Two display screens
· Two outputs (main and alarm)
· Adjustable for five types of alarm
· Adjustable maximum SV
· Output 1: changeover
relay. SSR and Triac driver,
standard signals Current: 0(4) – 20 mA
Voltage: 0(2) – 10 V
· Output 2: changeover relay
Adjustable
maximum and minimum output ranging
from 10 to 100%
Ambient
data
· Ambient temperature
range
0 to + 55 °C
· Ambient temperature
range
0 to + 40 °C
with side by side mounting
· Storage temperature
range
-40 to + 70°C
Climatic
conditions
≤ 75 % rel. humidity, (no condensation)
Output
· Output 1
Relay changeover contact 3A at 250V resistive load
Logic (SSR) 15V/20mA max
Triac Max Gate current = 50 mA
Voltage 0 – 10V , 2 – 10V / R Ioad = 500Ω min
Current 0 – 20 mA, 4 – 20 mA R load = 450Ω max
· Output 2 Relay
changeover contact 3A at 250VAC resistive
load
Supply
· Supply
voltage
85 – 265 VAC, 50 – 60 Hz
24 VDC (Optional)
· Power
consumption
≤3VA
Dimensions
· Bezel
size
96mm x 96mm
· Panel cut-out
92mm x 92mm